User's Manual
Chapter 2 - Installation
BreezeACCESS VL System Manual
42
2.3.3 Connecting the Grounding and Antenna
Cables
The Grounding screw (marked ) is located on the bottom panel of the outdoor
unit (in the new SU-A-ODU it is located on the backside of the unit). The Antenna
RF connector (marked
) is located on the top panel of the AU-ODU/SU-E-ODU.
To connect the grounding cable:
1 Connect one end of a grounding cable to the grounding terminal and tighten
the grounding screw firmly.
2 Connect the other end of the grounding cable to a good ground (earth)
connection.
To connect the RF cable (units with external antenna):
1 Connect one end of the coaxial RF cable to the RF connector on the top panel
of the unit
2 Connect the other end of the RF cable to the antenna.
3 The RF connectors should be properly sealed to protect against rain and
moisture.
Figure 2-7: Bottom Panel of the ODU
(all ODUs except to new SU-A-ODU, shown without the sealing assembly)