User's Manual
breezeAccessVLMib
BreezeACCESS VL System Manual
233
MIB Parameter Description Value/Range
Table that includes all available sub-
bands and all the frequencies in
these sub-bands.
*AutoSubBandFrequencySubsetEntry
(*AutoSubBandFrequencySubsetTable 1)
Applicable to SU/RB with SW
version 4.0 and higher. Not
accessible. An entry in the Auto
SubBand Frequency Subset Table.
*AutoSubBandFrequencySubsetBandIdx
(*AutoSubBandFrequencySubsetEntry 1)
Applicable to SU/RB with SW
version 4.0 and higher. Read-only.
The index of the applicable Sub
Band. This is the Sub Band ID of the
relevant entry in the Country
Dependent Parameters table.
Serves also as an index of the entry
in the Auto Sub Babd Frequency
Subset Table.
Integer
1-5
*AutoSubBandFrequencySubsetFrequen
cyIdx
(*AutoSubBandFrequencySubsetEntry 2)
Applicable to SU/RB with SW
version 4.0 and higher. Read-only.
The index of the applicable
frequency in the applicable Sub
Band. Serves also as an index of the
entry in the Auto Sub Band
Frequency Subset Table.
Integer
1-40
*AutoSubBandFrequencySubsetActive
(*AutoSubBandFrequencySubsetEntry 3)
Applicable to SU/RB with SW
version 4.0 and higher. The status
of an entry in the Auto Sub Band
Frequency Subset Table. The
frequency of an active entry will be
included in the final list of
frequencies to be used for scanning.
Integer
active (1) ,
notActive (2)
*AutoSubBandFrequencySubsetFrequen
cy
(*AutoSubBandFrequencySubsetEntry 4)
Applicable to SU/RB with SW
version 4.0 and higher. Read-only.
The frequency in MHz of the entry in
the Auto Sub Band Frequency
Subset table.
DisplayString
*ATPC
(*AirInterface 13)
ATPC parameters
*AtpcOption
(*ATPC 1)
Applicable to all units.
Enabling/disabling the ATPC
Algorithm
Integer
disable (1)
enable (2)
na (255)
*DeltaFromMinSNRLevel
(*ATPC 2)
Applicable to AU/BU. The Minimum
SNR Level plus the value of this
parameter define the maximum
desired level of the average SNR at
the AU/BU. If the ATPC Option is
enabled, than if the received SNR is
above the maximum desired level,
the AU/BU will transmit Power-Down
messages to the applicable SU/RB.
Integer
4-20 (dB)
*MinimumSNRLevel
(*ATPC 3)
Applicable to AU/BU. Defines the
minimum desired level in dB of the
average SNR at the AU/BU. Below
this level, if ATPC Option is enabled,
the AU/BU will transmit ATPC
Power-Up messages to the
applicable SU/RB.
Integer
4-60 (dB)
*MinimumIntervalBetweenATPC
Messages
(*ATPC 4)
Applicable to AU/BU. The minimal
time between consecutive power-
up/power-down messages.
Integer
Range: 1 to 3600 (seconds)