User's Manual

Appendix E - BreezeACCES VL MIB
BreezeACCESS VL System Manual
224
MIB Parameter Description Value/Range
(*MacAddressDenyList 2) BreezeNET B units. Add a MAC address
to the MAC Address Deny List Table
*MacAddressDenyListRemove
(*MacAddressDenyList 3)
Applicable to AU only. Not applicable to
BreezeNET B units. Remove a MAC
address from the MAC Address Deny List
Table
MAC Address
*NumberOfMacAddressesInDenyList
(*MacAddressDenyList 4)
Applicable to AU only. Not applicable to
BreezeNET B units. Read only. The
number of MAC addresses in the MAC
Address Deny List Table.
Integer
Range: 0 to 100
Na (255)
*MacAddressDenyListAction
(*MacAddressDenyList 5)
Applicable to AU only. Not applicable to
BreezeNET Bunits. Defines the action to
be used by the Mac Address Deny List.
Integer
denyList (1),
allowedList (2),
na (255)
*PortsControl
(*BridgeParameters 11)
Ports Control parameters. Applicable to
SU/RB only.
*EthernetPortControl
(*PortsControl 1)
Applicable to SU/RB only.
Enable/disable the Ethernet port. When
disabled, only data frames are blocked.
Management frames are accepted.
Integer
disable (1),
enable (2),
na (255)
E.2.6 Air Interface Parameters
MIB Parameter Description Value/Range
*AirInterface
(breezeAccessVLMib 6)
Applicable to all units. Air Interface
parameters.
*ESSIDParameters
(*AirInterface 1)
Applicable to all units. ESSID
Parameters.
*ESSID
(*ESSIDParameters 1)
Applicable to all units. The Extended
Service Set ID (ESSID) used to
prevent the merging of collocated
systems. The ESSID is accessible
only with the write community string
(administrator password).
DisplayString (SIZE(31))
Up to 31 printable case
sensitive ASCII characters.
*OperatorESSIDOption
(*ESSIDParameters 2)
Applicable to AU/BU only.
Enabling/disabling the use of the
Operator ESSID
Integer
disable (1)
enable (2)
na (255)
*OperatorESSID
(*ESSIDParameters 3)
Applicable to AU/BU only. A
secondary ESSID to support easy
installation of SUs as well as the use
of the Best AU/BU feature.
Accessible only with SNMP Write
Community string (administrator
password).
DisplayString (SIZE(31))
Up to 31 printable case
sensitive ASCII characters.
*RunTimeESSID
(*ESSIDParameters 1)
Applicable to SU/RB only. The
ESSID of the associated AU/BU.
Accessible only with SNMP Write
Community string (administrator
password).
DisplayString (SIZE(31))
Up to 31 printable case
sensitive ASCII characters.
*MaximumCellDistance
(*AirInterface 2)
Applicable to all units. For AU/BU:
read-write. For SU/RB: read-only.
The distance is learned from the
AU/BU. In units with SW version 2.0
and up - applicable only when the
Cell Distance Mode is set to Manual.
Integer
Range: For units with SW
version bellow version 2.0
the range is 0 - 50000
Meters.
For units with SW version