User's Manual

Menus and Parameters
Operation and Administration
143
4.2.6.2.15.5 Reset Spectrum Analysis Information
The Reset Spectrum Analysis Information option enables resetting the spectrum
analysis counters.
4.2.6.2.15.6 Spectrum Analysis Information Display
The Spectrum Analysis Information Display option enables viewing the results of
the last analysis process. The displayed information includes the following details
for each channel:
Frequency in MHz
Signal Count: The number of signals (excluding OFDM frames with the
correct bandwidth) in the channel.
Signal SNR: The approximate SNR of signals (excluding OFDM frames with
the correct bandwidth) in the channel.
Signal Width: The average width in microseconds of signals (excluding OFDM
frames with the correct bandwidth) in the channel.
OFDM Frames: The number of OFDM frames with the correct bandwidth
detected in the channel.
4.2.6.2.15.7 Spectrum Analysis Information Display - Continuous
The Spectrum Analysis Information Display - Continuous option is available only
when the analysis process is active. It enables viewing the continuously updated
results of the current analysis process. The displayed information includes the
same details available for a regular Spectrum Analysis Information Display
option.
4.2.6.2.16 Lost Beacons Transmission Watchdog Threshold
When it is unable to send beacon frames for a predetermined period of time, such
as in the case of interferences, the AU resets itself. The Lost Beacons
Transmission Threshold parameter represents the number of consecutive lost
beacons after which the unit will reset itself.
The range for this parameter is 100 – 1000 or 0. When the parameter is set to 0,
this feature is disabled, i.e. internal refresh will never be performed.
The default value is 218.
4.2.6.2.17 Disassociate (AU only)
The Disassociate feature enables disassociating all SUs associated with the AU or
a selected SU. This feature is useful during configuration changes, enabling to