User's Manual
Operation Verification
Commissioning
77
3.5.2 Indoor Unit Verification
To verify the correct operation of the indoor equipment, examine the LED
indicators located on the top panel of the SU IDU and AU IDU units, or on the
front panel of the BS-AU module.
Table 3-6 provides information for the BS-AU IDU LEDs. Table 3-7 lists the LEDs
of the PS1073 IDU.
Table 3-6: BS-AU LEDs
Name Description Functionality
W-LINK Wireless link activity
Green - At least one SU is associated.
Blinking Red - No SU is associated.
Off - Wireless link is disabled.
ODU CURRENT
CONSUMPTION
Current Consumption of
the Outdoor Unit
Red - over current.
Blinking Red - open circuit or below
anticipated current consumption.
Green - within tolerance.
ODU STATUS Outdoor Unit Self-test
Green - Self test passed and ODU
ready for operation.
Blinking Amber - Testing (not ready
for operation)
Red - fatal failure.
IDU PWR
Power indication for the
Indoor Unit
Green - IDU power is OK.
Off - no power is supplied to the IDU.
ALARM
Indoor Unit Alarm
Indication
Red - a fatal failure indication.
Off - IDU is functioning properly.
Table 3-7: PS1073 SU IDU / AU-SA IDU LEDs
Name Description Functionality
POWER Power Indication
Green – IDU power is OK
Off – No power or power failure
ETH
Self test and end-to-
end Ethernet
connectivity
Off – No Ethernet connectivity has
been detected between the outdoor
unit and the device connected to the
indoor unit.