The Info Screens menu includes the following options:
! Show Unit Status
! Show Basic Configuration
! Show Advanced Configuration
! Show Country Dependent Parameters
! Show All Parameters
Show Unit Status
The Show Unit Status menu is a read only menu that displays the
current values of the following parameters:
! Unit Name: As defined in Unit Control menu.
! Unit Type: Identifies the unit's function: AU-BS (a modular access
unit), AU-SA (a stand-alone access unit), SU-3-1D (subscriber unit
that supports a gross CPE rate of 3 Mbps and a single Ethernet
device), SU-6-1D (subscriber unit that supports a gross CPE rate of
6 Mbps and a single Ethernet device), SU-6-BD (subscriber unit that
supports a gross CPE rate of 6 Mbps and a full LAN), or SU-54-BD
(subscriber unit that supports a gross CPE rate of 54 Mbps and a
full LAN).
! Unit MAC Address: The unit's unique IEEE MAC address.
! Current Number of Associations (AU only): The total number of
SUs associated with this AU. This number may include units that
are not currently active since there is no aging algorithm for
associated SUs.
NOTE
An SU is only removed from the list of associated SUs under the following conditions:
a. A SNAP frame is received from another AU indicating that the SU is now associated
with the other AU.
b. The SU failed to respond to a certain number of consecutive frames transmitted by
the AU and is considered to have "aged out".
! Number of Associations Since Last Reset: In SUs - displays the
total number of associations with any AU since the last reset,
including duplicate associations with the same AU. In AUs -
displays the number of SUs that have associated with the AU since
the last reset, including duplicate associations with the same SU.
! Unit Status (SU only): The current status of the SU. There are two
status options: