3-13
Table 3-7: PS1036 SU IDU / AU-SA IDU LEDs
Name Description Functionality
POWER Power Indication
! Orange - 48VDC is present on the RADIO
port.
! Off - No power is supplied to the RADIO
port.
LINK Self test and end-to-
end Ethernet
connectivity
! Off – No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit.
! Green– Self-test passed and Ethernet
connection confirmed by the outdoor unit
(Ethernet integrity check passed).
Table 3-8: PS1073 SU IDU / AU-SA IDU LEDs
Name Description Functionality
POWER Power Indication
! Green – IDU power is OK
! Off - No power or power failure
ETH Self test and end-to-
end Ethernet
connectivity
! Off – No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit.
! Green– Self-test passed and Ethernet
connection confirmed by the outdoor unit
(Ethernet integrity check passed).
Verifying the Ethernet Connection
(Modular Base station)
Once you have connected the unit to an Ethernet outlet, verify that the
Ethernet Integrity Indicator, which is the yellow LED embedded in the
10/100 BaseT connector, is on. This indicates that the unit is
connected to an Ethernet segment. The Ethernet Activity Indicator,
which is the green embedded LED, should blink whenever the unit
receives or transmits traffic on the 10/100 BaseT port.