Chapter 3 - Commissioning
BreezeACCESSS VL System Manual
3-12
Indoor Unit Verification
To verify the correct operation of the indoor equipment, examine the
LED indicators located on the top panel of the SU IDU and AU IDU
units, or on the front panel of the BS-AU-VL module.
Table 3-6 provides similar information for the BS-AU IDU LEDs. Table
3-7 lists the LEDs of the PS1036 IDU and their associated indications.
Table 3-8 lists the LEDs of the PS1073 IDU.
Table 3-6: BS-AU LEDs
Name Description Functionality
W-LINK Wireless link activity
! Green - At least one SU is associated.
! Blinking Red - No SU is associated.
! Off - Wireless link disabled.
ODU CURRENT
CONSUMPTION
Current Consumption of
the Outdoor Unit
! Red - over current.
! Blinking Red - open circuit or below
anticipated current consumption.
! Green - within tolerance.
ODU STATUS Outdoor Unit Self-test
! Green - Self test passed and ODU ready
for operation.
! Blinking Amber - Testing (not ready for
operation)
! Red - fatal failure.
IDU PWR Power indication for the
Indoor Unit
! Green - IDU power OK.
! Off - no power is supplied to the IDU.
ALARM Indoor Unit Alarm
Indication
! Red - a fatal failure indication.
! Off - IDU is functioning properly.