User's Manual

Chapter 3 - Commissioning
BreezeACCESSS VL System Manual
3-2
Configuring Basic Parameters
After completing the installation process, as described in the preceding
chapter, the basic parameters must be configured to ensure that the
unit operates correctly. Once the basic parameters have been
configured, additional parameters can be remotely configured via the
Ethernet port or the wireless link using Telnet or SNMP management, or
by loading a configuration file.
Refer to Working With the Monitor Program
on page 4-2 for information
on how to access the Monitor program using Telnet and how to use it.
The Basic Configuration menu includes all the parameters necessary for
the initial installation and operation of BreezeACCESS VL Subscriber
and Access Units. In many installations, most of these parameters
should not be changed from their default values. The basic parameters
and their default values are listed in Table 3-1.
Refer to Chapter 4 - Operation and Administration
for detailed
information on the applicable parameters.
Table 3-1: Basic Parameters
Parameter Default Value Comment
Ethernet Port Negotiation Mode (in
Unit Control Parameters)
Auto Negotiation
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Options Disable
Access to DHCP AU: From Ethernet Only
SU: From Wireless Only
ESSID ESSID1
Sub Band Select 1 Applicable only if more
than one Sub Band is
available
Frequency Subset Definition (SU) A (All) The list of frequencies is
in accordance with the
Sub Band.