User's Manual

Connecting the Indoor-to-Outdoor Cable
Manual Revision 1.0
2-11
Connecting the Indoor-to-Outdoor
Cable
Units with an installed waterproof seal
1. Remove the two screws holding the waterproof seal to the outdoor
unit and remove the waterproof seal.
2. Unscrew the top nut from the waterproof seal.
Figure 2-4: The Waterproof Seal
3. Route a straight Cat. 5 Ethernet cable (8-wire, 24 AWG) through
both the top nut and the waterproof seal.
NOTE
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer.
See list of approved cables and length limitations in Indoor-to-Outdoor Cables on page
2-5.
4. Insert and crimp the RJ-45 connector. Refer to Appendix C for
instructions on preparing the cable.
5. Connect the Ethernet cable to the outdoor unit RJ-45 connector.
To connect the indoor-to-outdoor cable: