User's Manual

Chapter 1 - System Description
BreezeACCESSS VL System Manual
1-8
Standalone “Micro-cell” Access Unit
The standalone AU-D/E-SA Access Unit is very similar to the
AU-D/E-BS unit. The AU-D/E-SA-ODU outdoor unit is very similar to
the AU-D/E-BS-ODU outdoor unit (identical functionality, but the units
are not interchangeable). The available antennas for D model units are
the same as those of the AU-D-BS Access Unit. The main difference is in
the structure of the indoor part; in the AU-D/E-SA Access Unit the
indoor unit is a standalone desktop or wall-mountable unit (the same
Universal IDU that is also used in the SU) rather than a 19” module.
The IDU connects to the network through a standard IEEE 802.3
Ethernet 10/100BaseT (RJ 45) interfaces and is powered from the
110/220 VAC mains. The indoor unit is connected to the outdoor unit
via a Category 5 Ethernet cable. This cable carries Ethernet traffic
between the indoor and the outdoor units, and also transfers power
(54 VDC) and control from the indoor unit to the outdoor unit.
NOTE
The AU-D/E-SA-ODU and the AU-D/E-BS-ODU are not interchangeable:
The AU-D/E-SA-ODU cannot be used with the BS-AU; the AU-D/E-BS-ODU cannot be
used with the Universal IDU.