User's Manual
Appendix F - Parameters Summary
BreezeACCESSS VL System Manual
F-4
Air Interface Parameters
Table F-3: Air Interface Parameters
Parameter Unit Range Default Run-Time
ESSID AU, SU Up to 31 printable ASCII
characters
ESSID1 No
Operator ESSID
Option
AU
! Disable
! Enable
Enable No
Operator ESSID AU Up to 31 printable ASCII
characters
ESSID1 No
Best AU Support SU
! Disable
! Enable
Disable No
Number of
Scanning Attempts
SU 1 – 255 4 No
Preferred AU MAC
Address
SU MAC Address 00-00-00-00-00-00
(no preferred AU)
Yes
Scanning Mode SU Passive, Active Passive No
Cell Distance Mode AU Automatic, Manual Automatic No
Maximum Cell
Distance
AU 0-54 (Km)
0 means no compensation
0 (no
compensation)
Yes
Fairness Factor AU 0 – 100 (%) 100 (%) No
Arbitration Inter-
Frame Spacing
AU, SU
! 1 time slot
! 2 time slots
2 time slots Yes
Wireless Trap
Threshold
AU 1-100 (%) 30 (%) Yes
Maximum Number
of Associations
AU 1 – 512 512 Yes
Sub Band Select* AU, SU According to the Country
Code
1 No
Frequency AU According to the Sub Band The lowest
frequency in the
Sub Band
No
DFS Option** AU
! Disable
! Enable
Dependent on
Country DFS
Support: If DFS is
supported by the
country code then
the default will be
Enable, else it will
be Disable.
No
Frequency Subset
Definition (in AU)**
AU According to the Sub Band. A
list of frequency indexes or A
for all frequencies supported
by the Sub Band
A
No
Frequency Subset
Definition (in SU)
SU According to the Sub Band. A
list of frequency indexes or A
for all frequencies supported
by the Sub Band
A (All)
No