User's Manual
Parameters Summary
Manual Revision 1.0
F-3
Table F-1: Unit Control Parameters
Parameter Unit Range Default Run-Time
Ethernet Port
Negotiation Mode
AU, SU
! Force 10 Mbps and
Half-Duplex
! Force 10 Mbps and
Full-Duplex
! Force 100 Mbps and
Half-Duplex
! Force 100 Mbps and
Full-Duplex
! Auto Negotiation
Auto Negotiation No
Change System
Location
AU, SU Up to 34 printable ASCII
characters
None Yes
Manual Feature
Upgrade
AU, SU License string: 32 to 64
hexadecimal digits
None No
IP Parameters
Table F-2: IP Parameters
Parameter Unit Range Default Run-Time
IP Address AU, SU IP address 10.0.0.1 No
Subnet Mask AU, SU IP address 255.0.0.0 No
Default Gateway
Address
AU, SU IP address 0.0.0.0 No
DHCP Option AU, SU
! Disable
! DHCP Only
! Automatic
Disable No
Access to DHCP AU, SU
! From Wireless Only
! From Ethernet Only
! From Both Wireless and
Ethernet
AU: From Ethernet
Only
SU: From Wireless
Only
No