User's Manual
Appendix E - Supported MIBs and Traps
BreezeACCESSS VL System Manual
E-28
Table E-10: Security Parameters
MIB Parameter Description Value/Range
*PromiscuousAuthenticationMode
(*SecurityParameters 6)
Applicable to AU/RB.
Enabling/disabling the
promiscuous mode, where
any SU can be authenticated
by and communicate with the
AU.
Integer
disable (1)
enable (2)
*Key1
(*SecurityParameters 7)
Applicable to all units. Key
number 1. Accessible only
with SNMP Write Community
String (administrator
password).
DisplayString
32 hexadecimal
digits
*Key2
(*SecurityParameters 8)
Applicable to all units. Key
number 2. Accessible only
with SNMP Write Community
String (administrator
password).
DisplayString
32 hexadecimal
digits
*Key3
(*SecurityParameters 9)
Applicable to all units. Key
number 3. Accessible only
with SNMP Write Community
String (administrator
password).
DisplayString
32 hexadecimal
digits
*Key4
(*SecurityParameters 10)
Applicable to all units. Key
number 4. Accessible only
with SNMP Write Community
String (administrator
password).
DisplayString
32 hexadecimal
digits
Performance Parameters
Table E-11: Performance Parameters
MIB Parameter Description Value/Range
*PerformanceParams
(breezeAccessVLMib 10)
*RTSThreshold
(*PerformanceParams 1)
Applicable to SU and AU. Not
applicable to BreezeNET B
products. The minimum frame
size that requires an
RTS/CTS handshake.
Integer
20-1600 (bytes)
na (65535)
*MinContentionWindow
(*PerformanceParams 3)
Applicable to SU and AU. Not
applicable to BreezeNET B
products. The initial value to
be used by the contention
window calculation algorithm.
A value of 0 disables the
back-off algorithm and should
be used only in point-to-point
applications.
Integer
0, 7, 15, 31, 63,
127, 255, 511,
1023.
na (65535)
*MaxContentionWindow
(*PerformanceParams 4)
Applicable to SU and AU. Not
applicable to BreezeNET B
products. The maximum value
to be used by the contention
window calculation algorithm.
Integer
7, 15, 31, 63, 127,
255, 511, 1023
na (65535)