User's Manual
Appendix E - Supported MIBs and Traps
BreezeACCESSS VL System Manual
E-18
Table E-7: Air Interface Parameters
MIB Parameter Description Value/Range
*ApplicableModulationLevel
(*TransmitPowerEntry 2)
Applicable to all units. Read-
only. The applicable
modulation level for an entry
in the Transmit Power
parameters table. Level 8 is
not applicable to units with
HW revision A.
Level1to5 (1)
Level6 (2)
Level7 (3)
Level8 (4)
*MaximumTxPowerRange
(*TransmitPowerEntry 3)
Applicable to all units. Read-
only. The allowed range for
the *TxPower parameter at
the applicable modulation
level.
DisplayString
Range: -10 to the maximum
allowed for the applicable
modulation level.
*TxPower
(*TransmitPowerEntry 4)
Applicable to all units.
AU/BU: The transmit power
defined for the applicable
modulation level.
SU/RB: If ATPC is disabled,
this is The transmit power
defined for the applicable
modulation level. If ATPC is
enabled, it serves as the
initial transmit power for the
ATPC algorithm.
DisplayString
Range:
In SU/RB: The range is -10
dBm to the power value
defined by
*MaximumTxPower for the
applicable modulation level.
In AU/BU: The range is -10
dBm to the power value
defined by
*MaximumTxPowerRange
for the applicable modulation
level
*CurrentTxPower
(*TransmitPowerEntry 5)
Applicable to SU/RB.
The actual transmit power in
dBm at the applicable
modulation level.
DisplayString
Range: -
17 to the maximum
value defined by
*MaximumTxPowerRange
for the applicable modulation
level.
*MaximumTransmitPowerTable
(*AirInterface 6)
Applicable to SU /RB. Not
accessible. Maximum
Transmit Power parameters
table.
*MaximumTransmitPowerEntry
(*TransmitPowerTable 1)
Applicable to SU/RB. Not
accessible. An entry in the
Maximum Transmit Power
parameters table.
*MaximumTransmitPowerIdx
(*MaximumTransmitPowerEntry 1)
Applicable to SU/RB. Read-
only. An index of an entry in
the Maximum Transmit
Power parameters table.
Integer
1-4
*MaxTxApplicableModulationLevel
(*MaximumTransmitPowerEntry 2)
Applicable to SU/RB. Read-
only. The applicable
modulation level for an entry
in the Maximum Transmit
Power parameters table.
Level 8 is not applicable to
units with HW revision A.
Level1to5 (1)
Level6 (2)
Level7 (3)
Level8 (4)
*DefinedMaximumTxPowerRange
(*MaximumTransmitPowerEntry 3)
Applicable to SU/RB. Read-
only. The allowed range for
the *MaxTxPower
parameter at the applicable
modulation level.
DisplayString
Range: -10 to the maximum
allowed for the applicable
modulation level.