User's Manual

breezAccessVLMib
Manual Revision 1.0
E-17
Table E-7: Air Interface Parameters
MIB Parameter Description Value/Range
*MaximumCellDistance
(*AirInterface 2)
Applicable to all units. For
AU/BU: read-write. For
SU/RB: read-only. The
distance is learned from the
AU/BU. In units with SW
version 2.0 and up -
applicable only when the
Cell Distance Mode is set to
Manual. The highest
distance from the AU/BU of
any SU/RB served by it.
Affects the maximum time
the units wait for a response
message and the slot size
by taking into account the
round trip propagation
delay.
Integer
Range: For units with SW
version bellow version 2.0
the range is 0 - 50000
Meters.
For units with SW version
2.0 and up the range is 0 to
54 Kilometers.
0 means no compensation
(minimum slot size, maximal
delay timeout).
*AIFS
(*AirInterface 3)
Applicable to AU and SU.
Not applicable to
BreezeNET B products.
Arbitration Inter-Frame
Spacing (AIFS). This is the
number of time slots that
define the DIFS.
(DIFS=SIFS+AIFS). A value
of 1 should be used only in
point-to-point applications to
allow one unit to have
advantage over the other
unit.
Integer
oneSlot (1)
twoSlots (2)
na (255)
*WirelessTrapThreshold
(*AirInterface 4)
Applicable to AU/BU only. A
wireless link quality
threshold, expressed in % of
retransmissions, for sending
the
brzaccVLAUWirelessQuality
TRAP.
This trap indicate whether
the quality has gone below
or above the specified
threshold
Integer
1-100 (%)
*TransmitPowerTable
(*AirInterface 5)
Applicable to all units. Not
accessible. Transmit Power
parameters table.
*TransmitPowerEntry
(*TransmitPowerTable 1)
Applicable to all units. Not
accessible. An entry in the
Transmit Power parameters
table.
*TransmitPowerIdx
(*TransmitPowerEntry 1)
Applicable to all units. Read-
only. An index of an entry in
the Transmit Power
parameters table.
Integer
1-4