NOTE
The ESSID string is case sensitive.
Operator ESSID Parameters (AU only)
The Operator ESSID Parameters submenu includes the following
parameters:
Operator ESSID Option
The Operator ESSID Option enables or disables the use of Operator
ESSID for establishing association with SUs.
The default is Enable.
Operator ESSID
The Operator ESSID parameter defines the Operator ESSID.
Valid values: A string of up to 31 printable ASCII characters.
The default value is ESSID1.
NOTE
The Operator ESSID string is case sensitive.
Frequency Definition Parameters
The parameters that determine the frequency to be used are set in the
AU. The SU should be configured with a minimal set of parameters to
ensure that it will be able to automatically detect and use the frequency
used by the AU, including possible changes in this frequency.
To simplify the installation process the SU scans a definable frequencies
subset after power-up. If the Best AU feature is enabled, the SU will
scan the defined subset and the operating frequency will be determined
by the Best AU mechanism (including the optional use of the Preferred
AU feature). Otherwise the SU will try to associate with the first AU it
finds. If no AU is found, the SU will start another scanning cycle.
Each unit is delivered with one or more pre-configured Sub-Bands,
according to the country code. These sets of parameters include also the
frequencies that can be used and the bandwidth. If more than one Sub-
Band is available, the sub-band to be used can be selected in both the
AU and the SU. If only one Sub-Band is supported, then the sub-band
selection option is not available.