User's Manual
Aligning the Antenna (A7 model)
SU-R Installation Manual 13 BreezeACCESS II Series
2.
From the
main menu
, type 4 to access the
Site Survey
menu. Type 4 to start the
Continuous
Link Quality Display
. Each line in the display includes the number of frames that were
received since the last measurement (total Rx) and the average RSSI for these frames.
3.
Rotate the antenna left and/or right (or tilt it upward/downward) until you reach the point of
maximum RSSI reading. Make sure that at all times, the front of the antenna faces the general
direction of the Base Station.
4.
For proper operation, the RSSI reading should be at least 38 units. When the maximum
reading is less than 43 units, try to improve it by placing the antenna at a higher point or in a
different location. For best performance it is recommended that the RSSI be higher than 65.
5.
Press the
Esc
key to stop the test.
6.
Secure the antenna to guarantee that it will remain in the selected position.