User's Manual
Configuring System Parameters
SU-R Installation Manual 9 BreezeACCESS II Series
Operate the monitor program as follows:
•
Type an option number to open/activate the option. You may need to press the Enter key in
some cases.
•
Press the Esc key to exit a menu or an option.
•
You can log-out and exit the monitor program from the
Main Menu
by simultaneously
pressing the
Ctrl
and
X
keys. The session is terminated automatically, after a specific time of
inactivity determined by the Log-out Timer. The default value for the Log-out Timer is 5
minutes.
•
Reset the unit after making configuration changes for the new values to take effect.
•
You can view the current parameters’ configuration by selecting 1 in the Main Menu to
Access the Info Screens menu, and than selecting 2 in the Info Screens menu to view the Basic
Configuration parameters.
3.2 Configuring Basic Parameters
The following system parameters must be configured for each specific installation:
•
ESSID
•
IP Parameters: DHCP Client and/or IP Address, Subnet Mask and Default Gateway Address
•
Transmit Antenna
Note:
You must select Reset Unit in the Unit Control menu for the changes to take effect.
Subscriber Units should be configured after the applicable Access Unit is operational.
See Appendix C for more details on the basic parameters.