User's Manual

Configuring System Parameters
SU-R Installation Manual 7 BreezeACCESS II Series
3. CONFIGURING SYSTEM PARAMETERS
After completing the installation process, as described in the preceding sections of this manual,
proceed with configuration of the basic system parameters.
This manual covers the configuration of basic installation parameters. Refer to the Administration
Manual for information related to other parameters.
Note:
Optionally, the product can be configured using Telnet over the Ethernet port, after setting
IP address. For further information, refer to Appendix B.
3.1 Getting Started with the Local Terminal
1.
Connect one end of the Monitor cable to the Monitor jack (marked MON) on the bottom
panel of the unit. Connect the second end of the cable to the COM port of the terminal. The
COM port connector on the Monitor cable is a 9 pin D-type plug.
2.
Run a terminal emulation program (e.g., ProComm or Windows HyperTerminal) using the
following setup:
Baud rate
9600
Data bits
8
Stop bits
1
Parity
None
Flow Control
Xon/Xoff
Connector
Available Com Port
3.
Press
Enter
. The
Select Access Level
menu appears. Select the access level according to
your authorized access level. You will be requested to enter your password. After entering
the correct password, press enter. The main menu appears (refer to Figure 3-1).
Unit Type