User's Manual

Appendix A
BreezeACCESS MMDS Series 23 SU-I-D Installation Manual
A.1.1 Installing the TPA 24
1. Choose one of the TPA 24 models according to the power level at the input
of the booster. In general the NH model is used. For installations with long
cables (high attenuation), the NL model should be used.
2. Choose one of the antenna connectors to be used for transmission.
3. Use the terminal to set the unit’s transmit diversity option to the selected
antenna.
Figure A-1. TPA 24 Installation
4. Connect the TPA 24 RF output directly to the transmit antenna.
5. Attach the TPA 24 RF input to the Power Inserter with the RF cable. The
Power Inserter must be installed indoors.
6. Connect the RF cable leading from the Power Inserter to the transmit antenna
on the BreezeACCESS unit.