User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing AUs
4Motion 457 System Manual
3.6.2.2 Configuring the Control Parameter
The control parameters enables controlling the operation of the AU.
To configure the control parameter, run the following command:
npu(config-au-1)# control shutdown-operation {normalOperation | reset |
shutdown}
Command
Syntax
npu(config-au-1)# properties [required-type <au4x4Modem | au2x2> ]
[port-1-power {shutDown | noShutDown} ] [port-2-power {shutDown |
noShutDown} ] [port-3-power {shutDown | noShutDown} ]
[port-4-power {shutDown | noShutDown} ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[required-type
<au4x4Modem
|au2x2>
Defines the AU card
configuration required: 4-ports or
2-ports. 2-ports AU is applicable
only for Macro Outdoor.
Optional au4x4Mo
dem
au4x4Mode
m
au2x2
[port-1-power
{shutDown |
noShutDown} ]
Controls power from AU card
port 1 to ODU
Optional No
Shutdown
shutDown
noShutDown
[port-2-power
{shutDown |
noShutDown} ]
Controls power from AU card
port 2 to ODU.
Optional No
Shutdown
shutDown
noShutDown
[port-3-power
{shutDown |
noShutDown |} ]
Controls power from AU card
port 3 to ODU. Not applicable for
a 2-ports AU.
Optional No
Shutdown
shutDown
noShutDown
[port-4-power
{shutDown |
noShutDown} ]
Controls power from AU card
port 4 to ODU. Not applicable for
a 2-ports AU.
Optional No
Shutdown
shutDown
noShutDown
Command
Modes
au configuration mode