User Manual

Chapter 3 - Operation and Administration of the Macro BTS NPU Configuration
4Motion 448 System Manual
3.4.16.8.2 Displaying the Unique Identifier for the 4Motion Shelf
To display the unique identifier for the 4Motion shelf, run the following command:
npu# show site identifier
IMPORTANT
You must save the configuration (run the command npu# write) for a change in site identifier to take
effect after next reset.
Since the site identifier (Site Number) is used by AlvariSTAR management system to identify the
device, it is highly recommended not to modify it. If necessary, you must follow the Site Number
Change process described in the Device Driver Manual.
NOTE
To display the 4Motion shelf identifier, refer to “Displaying the Unique Identifier for the
4Motion Shelf” on page 448
.
Command
Syntax
npu(config)# site identifier <
site id <1-999999>>
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<site id
<1-999999>
>
Indicates the ID of the
4Motion shelf.
Mandatory N/A 1-999999
Command
Modes
Global configuration mode
Command
Syntax
npu# show site identifier
Privilege
Level
1