User Manual

Chapter 3 - Operation and Administration of the Macro BTS NPU Configuration
4Motion 442 System Manual
3.4.16.5.2 Clearing Dry-contact Output Alarms
After the system returns to its normal state, run the following command to clear
the dry-contact output alarm that you had raised:
npu(config)# no dry-contact OUT <alarm_num (1-3)>
After you run this command, the alarm that you had raised is cleared.
NOTE
After you have raised an alarm, clear this alarm when the system state returns to its normal
condition. For information, refer to,
“Clearing Dry-contact Output Alarms” on page 442.
For more information about displaying configuration information about a dry contact output alarm,
refer to
“Displaying Configuration Information for Dry-contact Input/Output
Alarms” on page 443
.
Command
Syntax
npu(config)# dry-contact OUT <alarm_num (1-3)> alarm <alarm name >
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<alarm_num
(1-3)>
Indicates the alarm number of
the dry contact output alarm
that is to be configured. This
alarm number corresponds to
a pin on the 25-pin micro
D-Type jack.
For more information about
pin numbers that correspond
to the alarm number, refer
Table 3-27.
Mandatory N/A 1-3
alarm <alarm
name>
Indicates the name of the
dry-contact alarm to be
raised.
Mandatory N/A Up to 256
characters
Command
Modes
Global configuration mode