Chapter 3 - Operation and Administration of the Macro BTS NPU Configuration
4Motion 415 System Manual
AVU: Includes a 1U high integral chamber for inlet airflow and a 1U high fan
tray with an internal alarm module. The AVU comprises 10 brush-less fans,
where 9 fans are sufficient for cooling a fully loaded chassis.
Power Feeder: The PIU can support a maximum current of 58 A (@-40.5 VDC).
In certain installations with a relatively high number of ODUs this current
may not be sufficient to power the shelf and all the ODUs. In such
installations the ODU Power Feeder is used as an additional power source
providing power (-48V DC) to ODUs. It transfers transparently all signals
between the AU and the ODU, while injecting DC power received from an
external source. Each ODU Power Feeder unit can serve up to four ODUs.
This section describes the commands to be used for:
“Configuring the PSU/PIU Modules” on page 415
“Configuring the GPS” on page 418
“Managing Power Feeders Configuration” on page 433
“Managing Dry-contact Input Alarms” on page 435
“Managing Dry-contact Output Alarms” on page 440
“Displaying Configuration Information for Dry-contact Input/Output Alarms”
on page 443
“Managing the Site General Information for the 4Motion Shelf” on page 445
“Managing the Unique Identifier for the 4Motion Shelf” on page 447
“Displaying the Vendor Identifier” on page 449
3.4.16.1 Configuring the PSU/PIU Modules
This section describes the commands to be used for:
“Enabling/Disabling the PSU, and PIU Modules” on page 416
“Configuring the PIU Hardware Version” on page 417