User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 541 System Manual
3.9.9.3 Restoring Default Values for Neighbor BS Configuration
Parameters
After enabling the Neighbor BS configuration mode you can restore the default
values for non-mandatory parameters in the following parameters tables:
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<specific-trigger-name> The Specific Trigger
name.
Mandatory N/A See
Table 3-3
0
<trigger-value> Defines the threshold
value for the Trigger.
Mandatory N/A See
Table 3-3
0
Command
Modes
bs neighbor bs configuration mode
Table 3-30: Neighbor Specific Trigger Names and Possible Value Ranges
Trigger Name Trigger Condition Action Possible Values
nbrspecific-horeq-cinr-max-nbs The C/N at the Serving BS is
below the Trigger threshold
(in dB)
Handover
Request
-64 to 63.5 in steps of 0.5
nbrspecific-horeq-rssi-max-nbs The RSSI at the Serving BS is
below the Trigger threshold
(in Bm)
-103.75 to -40 in steps of 0.25
nbrspecific-horeq-cinr-margin The C/N at the Neighbor BS
minus the C/N at the Serving
BS is above the Trigger
threshold (in dB)
-64 to 63.5 in steps of 0.5
nbrspecific-horeq-rssi-margin The RSSI at the Neighbor BS
minus the RSSI at the Serving
BS is above the Trigger
threshold (in dB)
--32 to 31.75 in steps of 0.25