User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 522 System Manual
Configure one or more of the Neighbor Advertisement parameters (refer to
Section 3.9.6.1).
Restore the default values of one or all of the Neighbor Advertisement
parameters (refer to Section 3.9.6.2).
You can display configuration information for the Neighbor Advertisement
parameters of a selected or all existing BSs (refer to Section 3.9.6.3).
3.9.6.1 Configuring Neighbor Advertisement Parameters
From the BS configuration mode, run the following command:
npu(config-bs-66053)# nbradvertise [triggersetup <(0 to 100 StepSize 0.1)>]
3.9.6.2 Restoring the Default Values of Neighbor Advertisement
Parameter
Since there is only one Neighbor Advertisement parameter, run any of the
following commands to restore it to the default value:
npu(config-bs-66053)# no nbradvertise
To configure the Neighbor Advertisement Parameters:
Command
Syntax
npu(config-bs-66053)# nbradvertise [triggersetup <(0 to 100
StepSize 0.1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[triggersetup <(0 to 100
StepSize 0.1)> ]
The periodic NBRADV
transmission interval, in
seconds
Optional 10 0 - 100 in
steps of 0.1
Command
Modes
bs configuration mode