User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 515 System Manual
3.9.4.5.2 Displaying Configuration Information for Power Control Maximum
EIRxP
The Maximum EIRxP parameter defines the maximum effective isotropic received
power at the BS for Initial ranging.
In the current release this parameter cannot be configured and is set by the value
in the vendor parameters file.
To display configuration for the Power Control Maximum EIRxP parameter, run
the following command:
npu# show pwrctrl-maxeirxp bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Power Control Maximum EIRxP parameter of BS 66053,
run the following command:
npu# show pwrctrl-maxeirxp bs 66053
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show pwrctrl-maxeirxp bs
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
TargetNi :<value>
AllowedIfLevel :<value>
Command
Modes
Global command mode
Command
Syntax
npu# show pwrctrl-maxeirxp bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1