Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 511 System Manual
3.9.4.3 Restoring Default Values for Power Control Configuration
Parameters
After enabling the Power Control configuration mode you can restore the default
values for parameters in the following parameters tables:
Noise and Interference Level (refer to Section 3.9.4.3.1)
Required C/N Level (refer to Section 3.9.4.3.2)
3.9.4.3.1 Restoring the Default Values of Power Control Target Noise and
Interference Level Parameters
To restore one or all of the Target Noise and Interference Level parameters to their
default values, run the following command:
npu(config-bs-66053-pwrctrl)# no nilevels [target-ni] [allowed-if-level]
You can restore only one parameter to its default values by specifying only that
parameter. For example, to restore only the target-ni to the default value, run the
following command:
npu(config-bs-66053-pwrctrl)# no nilevels target-ni
The parameter will be restored to its default value, while the other parameter will
remain unchanged.
[qam64-5by6 <(-20
to 50 StepSize 1)> ]
he C/N in dB required for
transmitting using 64QAM 5/6,
reported to the MS for power
control purposes.
Must be in the range from
requiredcnr-qam64-3by4 - 8 to
requiredcnr-qam64-3by4 + 7 (see
qam64-3by4 parameter above)
Optional 28 -20 to 50
Command
Modes
bs power control configuration mode
NOTE
In the current release, the command for restoring the default value for the Maximum EIRxP
parameter, npu(config-bs-66053-pwrctrl)# no maxeirxp, is not applicable and should not be used.
An attempt to restore the value to a default value using this command will be ignored (value is taken
from vendor file).