User Manual
Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 504 System Manual
3.9.3.2 Restoring Default Values for BS General Parameters
After enabling the BS configuration mode you can restore the default values for
one or all of the general BS parameters.
To restore one or all general BS parameters do their default value, run the
following command:
npu(config-bs-66053)# no general [operator-id] [bs-name]
[ul-def-rate-for-management] [dl-def-rate] [dl-def-rate-for-data]
[deployment]
You can restore one parameter to its default value by specifying only that
parameter. For example, to restore only the operator-id to its default value, run
the following command:
npu(config-bs-66053)# no general operator-id
The operator-id will be restored to its default value, while the other parameters
will remain unchanged.
To restore all parameters to their default value, run the following command:
npu(config-bs-66053)# no general
3.9.3.3 Displaying Configuration Information for BS General
Parameters
To display configuration information of the general parameters of a specific or all
BSs, run the following command:
NOTE
Refer to Section 3.9.3.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no general [operator-id] [bs-name]
[ul-def-rate] [dl-def-rate-for-management] [dl-def-rate-for-data]
[deployment]
Privilege
Level
10
Command
Modes
bs configuration mode