User Manual
Chapter 3 - Operation and Administration of the Macro BTS NPU Configuration
4Motion 242 System Manual
MS State Change parameters can be configured only by the vendor.
To display configuration information for the MS state change functionality, run
the following command:
npu# show msscfn
The following table provides some details on these parameters:
Command
Syntax
npu# show msscfn
Privilege
Level
1
Display
Format
MS State Change Function Configuration :
msscfnTimerMsscRsp <value>
msscfnCounterMsscRspMax <value>
msscfnTimerSbcHold <value>
msscfnTimerRegHold <value>
msscfnTimerMsscDrctvReq <value>
msscfnCounterMsscDrctvReqMax <value>
Command
Modes
Global command mode
Parameter Description
msscfnTimerMsscRsp The period, in milliseconds for which the NPU waits for an
acknowledgement for the MS state change response. If the NPU does
not receive an acknowledgement within this period, it retransmits the MS
state change response.
msscfnCounterMsscRspMax The maximum number of times, the NPU retransmits the MS state
change response.
msscfnTimerSbcHold The period, in milliseconds, within which the basic capabilities
negotiation procedure should be completed. At the end of this period, the
NPU starts the authentication/ registration procedure for the MS,
depending on accepted authentication policy.