User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 623 System Manual
npu# show ranging-general bs
3.9.20 Managing Alarm Threshold Parameters
After enabling the BS configuration mode, you can execute the following tasks:
Configure one or more of the Alarm Threshold parameters (refer to
Section 3.9.20.1).
Restore the default values of some or all of the Alarm Threshold parameters
(refer to Section 3.9.20.2).
Command
Syntax
npu# show ranging-general bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Ranging General
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display the Ranging General
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
StartofRangingCodes :<value>
MaximumCellRadius(km) :<value>
Command
Modes
Global command mode