User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 594 System Manual
3.9.14.2 Restoring the Default Values of Authentication Parametes
To restore the default values of some or all of the Authentication parameters, run
the following command:
npu(config-bs-66053)# no auth-general [suspendedeapprocthrshld]
[activemsthrshld] [maxeaproundsthrshld]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the activemsthrshld and
[activemsthrshld <(0
to 1024 StepSize 1)> ]
Threshold for the number
of MSs in active operation
state (not Idle) served by
the BS. Exceeding this
threshold will set the
alarm “Excessive MS
number”.
A value of 0 means that
the alarm is disabled.
Optional 1024 0 to 1024
[maxeaproundsthrshl
d <(0 to 100 StepSize
1)> ]
Threshold for the number
of EAP rounds in one
direction in the same EAP
session. When exceeding
this threshold; alarm is
set. May be used to
protect the system from
hazard EAP sessions with
extreme number of
messaging round trips. A
value of "0" means the
alarm is disabled.
A value of 0 means that
the alarm is disabled.
In the current release the
relevant alarm is not
supported.
Optional 100 0 to 100
Command
Modes
bs configuration mode
IMPORTANT
When creating a new BS, the Authentication dflt-auth-ip-address mandatory parameter must be
configured.