User Manual

Chapter 3 - Operation and Administration of the Macro BTS Managing BSs
4Motion 570 System Manual
3.9.12.2.5 Configuring Airframe Downlink Data Zone Parameter
To configure the Airframe Downlink Data Zone parameter, run the following
command:
npu(config-bs-66053-airframe)# dldatazone permbase <(0 to 31 StepSize 1)>
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[permbase <(0 to 69
StepSize 1)> ]
The permutation base used
in the feedback zone
Mandatory
when
creating a
new BS.
N/A 0 - 69
Command
Modes
bs airframe configuration mode
IMPORTANT
When creating a new BS, the Airframe Uplink Feedback Zone mandatory permbase parameter
must be configured.
Command
Syntax
npu(config-bs-66053-airframe)# dldatazone permbase <(0 to 31 StepSize
1)>
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[permbase <(0 to 31
StepSize 1)> ]
The permutation base used
in the downlink data zone
Mandatory
when
creating a
new BS.
N/A 0 - 31
Command
Modes
bs airframe configuration mode