User Manual

Chapter 4 - Operation and Administration of the Micro BTS GPS Menu
4Motion 741 System Manual
4.9.1.5 UTC Time and Date
The UTC (Coordinated Universal Time) date and time. Configurable only if the GPS
Type is set to None. Otherwise it is the read-only data received from the GPS
receiver.
The format is hh: mm: ss, dd/mm/yyyy
hh between 0 and 23, mm between 0 and 59, ss between 0 and 59, dd/mm with
usual date and month rules, yyyy between 2006 to 9999.
4.9.1.6 Hold Over Passed Timeout
Applicable only if a GPS receiver is used. Defines the period, in minutes, for which
the device provides holdover when the GPS loses synchronization with its
satellites.
The range is from 0 to 2880 minutes. The default is 480 minutes.
4.9.1.7 Stop TX After Hold Over Timeout
Applicable only if a GPS receiver is used. Indicates whether the BTS should stop
data transmission if the GPS lost synchronization with its satellites and the
holdover passed timeout has occurred (Enable/Disable). When enabled, the BTS
will stop transmitting after being in holdover state for more than Holdover Passed
Timeout. The default is Enable.
4.9.1.8 Time Zone Offset From UTC
The offset of the local time from the UTC.
The range is -12:00 to +13:00 in 30 minutes resolution. The default is +00.00.
4.9.1.9 Local Time and Date
A read-only display of the local date and time (using 24-hour clock) as calculated
using the UTC Time and Date and taking into account the Time Zone Offset From
UTC and Daylight Saving Time parameters. The format is: hh:mm:ss;
dd/mm/yyyy.
4.9.1.10 Daylight Saving Mode
The Daylight Saving Mode parameter is used to enable or disable the daylight
saving feature using the following Start Date, Stop Date and Advance Hour Factor
parameters. The default is Disable.