4.7.2.6 Air Frame Structure General
The Air Frame Structure General menu enables viewing/updating the values
configured for the following parameters:
“Cell ID”
“Preamble Group”
“Segment Number”
“Preamble Index”
“Total Uplink Duration”
“Operational Status Channel 1”
“Operational Status Channel 2”
“Neighbor with Beamforming”
4.7.2.6.1 Cell ID
The Cell ID (IDCell) used for preamble selection. The range is from 0 to 31.
4.7.2.6.2 Preamble Group
The preamble group (1 or 2). A value of 2 is applicable only for the following
combinations of Segment Number and Cell ID values:
Segment Number=0, Cell ID=0, 3, 6, 9, 12, 15.
Segment Number=1, Cell ID=1, 4, 7, 10, 13, 16.
Segment Number=2, Cell ID=2, 5, 8, 11, 14, 17
The default is 1.
4.7.2.6.3 Segment Number
The segment (BS) number in a three sector BS (0-2).
4.7.2.6.4 Preamble Index
Read-only. The Preamble Index used by the BS (0-113).
4.7.2.6.5 Total Uplink Duration
The total duration of the uplink in a frame, in slots (one slot equals 3 symbols).