User Manual

Chapter 4 - Operation and Administration of the Micro BTS The Monitor Program
4Motion 688 System Manual
4.2 The Monitor Program
4.2.1 Accessing the Monitor Program
1 Use the Monitor cable to connect the MON connector to the COM port of your
ASCII ANSI terminal or PC. The COM port connector on the Monitor cable is a
9 pin D type plug.
2 Run a terminal emulation program, such as HyperTerminal™.
3 Set the communication parameters as shown in the following table:
The password prompt is displayed. Enter the password and press the Enter key to
get to the Main menu. The default password is “installer”.
1 The PC used for accessing the Monitor program should be configured
according to the BTS Management Connectivity parameters (see “Connectivity”
on page 694).
2 Run the Telnet program connecting to the IP address of the connected port.
3 The Enter the password message is displayed. Enter the password and press
the Enter key to get to the Main menu. The default password is “installer”.
To access the Monitor program via the MON connector:
Table 4-1: COM Port Configuration
Parameter Value
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Flow Control Xon/Xoff
Port Connected COM port
To access the Monitor program using Telnet: