User Manual
Chapter 3 - Operation and Administration of the Macro BTS Troubleshooting
4Motion 679 System Manual
monitoring for source and destination interfaces or displaying configuration
information for a particular interface.
To enable port monitoring, you are required to configure:
Source interfaces: Refers to the FastEthernet or GigabitEthernet interface for
which incoming, outgoing or both types of traffic is to be monitored. You can
configure port monitoring for one or more source interfaces.
Destination interface: Refers to the interface where the packets are sent for
analysis.
Direction of the traffic that is to be monitored
The following table lists the interfaces that can be mirrored, and the port numbers
mapping to these interfaces:
This section describes the commands to be used for:
“Enabling the Port Monitoring Session” on page 680
“Disabling a Port Monitoring Session” on page 682
“Displaying Configuration Information for Source and Destination Interfaces”
on page 684
Table 3-34: Interface to Ethernet Port Mapping
Ethernet Port Interface Type Interface ID
AU1 Fast Ethernet 0/1
AU2 Fast Ethernet 0/2
AU3 Fast Ethernet 0/3
AU4 Fast Ethernet 0/4
AU5 Fast Ethernet 0/5
AU6 Fast Ethernet 0/6
AU7 Fast Ethernet 0/7
MGMT Fast Ethernet 0/8
CASCD Gigabit Ethernet 0/9