- 4Motion System Manual
- About This Manual
- Contents
- Chapter 1 - System Description
- 1.1 About WiMAX
- 1.2 4Motion Solution
- 1.3 The Base Transceiver Station
- 1.4 Element Management Systems
- 1.5 Specifications
- 1.5.1 Modem & Radio
- 1.5.2 Sensitivity (per channel)*
- 1.5.3 ODUs
- 1.5.4 Micro Outdoor BTS
- 1.5.5 AU - ODU Communication (Macro BTS)
- 1.5.6 Data Communication (Ethernet Interfaces)
- 1.5.7 Configuration and Management
- 1.5.8 Standards Compliance, General
- 1.5.9 Environmental
- 1.5.10 Mechanical and Electrical
- 1.5.11 Antennas
- Chapter 2 - Commissioning of the Macro BTS
- 2.1 Initial NPU Configuration
- 2.2 Completing the Site Configuration Using AlvariSTAR
- Chapter 3 - Operation and Administration of the Macro BTS
- 3.1 Using the Command Line Interface
- 3.1.1 Managing the Macro Outdoor BTS
- 3.1.2 Accessing the CLI
- 3.1.3 Command Modes
- 3.1.4 Interpreting the Command Syntax
- 3.1.5 Using the CLI
- 3.1.6 Managing Users and Privileges
- 3.1.7 Managing Secure Shell (SSH) Parameters
- 3.1.8 Managing the Session
- 3.2 Managing Software Upgrade
- 3.1 Using the Command Line Interface
Chapter 1 - System Description The Base Transceiver Station
4Motion 22 System Manual
1.3.5 Power Feeder
The PIU of the indoor Macro BTS can support a maximum current of 58 A (@-40.5
VDC). In certain installations with a relatively high number of ODUs this current
may not be sufficient to power the shelf and all the ODUs. In such installations
the ODU Power Feeder is used as an additional power source providing power (-48
VDC) to ODUs. It transfers transparently all signals between the AU and the ODU,
while injecting DC power received from an external source. Each ODU Power
Table 1-3: ODU Types
Band
(GHz)
ODU Frequency
Range (MHz)
ODU Port
Configuration
ODU Bandwidth
(MHz)
ODU Max Tx
Power (dBm)
BF
Support
2.3 2300-2360 1Rx by 1Tx Up to 10 36 No
2340-2400 1Rx by 1Tx Up to 10 36 No
2305 - 2317, 2348 - 2360
(includes WCS filter)
1Rx by 1Tx Up to 10 36 No
2300-2400 2Rx by 2Tx Up to 30 38 Yes
2.5 2496-2602 (band A) 1Rx by 1Tx Up to 10 36 No
2590-2690 (band B) 1Rx by 1Tx Up to 10 36 No
2485-2690 2Rx by 2TX Up to 30 38 Yes
2496-2602 (band A) 4Rx by 2Tx Up to 20 38 No
2590-2690 (band B) 4Rx by 2Tx Up to 20 38 No
2485-2690 4Rx by 2Tx Up to 20 38 Yes
2560-2570 4Rx by 2Tx Up to 10 37 No
3.3 3300-3355 1Rx by 1 Tx Up to 14 32 No
3345-3400 1Rx by 1Tx Up to 14 33 No
3.5 3400-3455 1Rx by 1Tx Up to 14 34 No
3445-3500 1Rx by 1Tx Up to 14 34 No
3500-3555 1Rx by 1Tx Up to 14 34 No
3545-3600 1Rx by 1Tx Up to 14 34 No
3400-3600 2Rx by 2Tx Up to 30 37 Yes
3400-3600 4Rx by 2Tx Up to 20 37 No
3400-3600 4Rx by 2Tx Up to 20 37 Yes
3.6 3650-3700 1Rx by 1Tx Up to 14 22 No
3600-3800 4Rx by 2Tx Up to 20 36 Yes