Chapter 3 - Operation and Administration of the Macro BTS Managing Software Upgrade
4Motion 100 System Manual
3.2.2.1 Executing the Upgrade Procedure
“Step 1: Configuring the TFTP Server”
“Step 2: Triggering Software Download”
“Step 3: Resetting and Booting the NPU Using the Shadow Image”
“Step 4: Making the Shadow Version Operational”
3.2.2.1.1 Step 1: Configuring the TFTP Server
To initiate the NPU software upgrade procedure, start with configuring the TFTP
server to be used for the software version download.
To configure the TFTP server, run the following command:
npu(config)# software version server <server ip>
NOTE
The operational image is the default image used for rebooting the NPU after system reset. The
shadow image is the downloaded image that you can use to boot up the NPU. However, the next
time the system is reset, it is the operational image that is used to boot up the NPU.
To execute the upgrade procedure:
IMPORTANT
An error may occur if you execute this command when another software download is already in
progress.
Command
Syntax
npu(config)# software version server <server ip>
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<server ip>
Denotes the IP address of the
TFTP server to be used for
the software version
download.
Mandatory N/A Valid IP
address