User Manual
Table Of Contents
- 4Motion System Manual
- About This Manual
- Contents
- Chapter 1 - System Description
- 1.1 About WiMAX
- 1.2 4Motion Solution
- 1.3 The Base Transceiver Station
- 1.4 Element Management Systems
- 1.5 Specifications
- 1.5.1 Modem & Radio
- 1.5.2 Sensitivity (per channel)*
- 1.5.3 ODUs
- 1.5.4 Micro Outdoor BTS
- 1.5.5 AU - ODU Communication (Macro BTS)
- 1.5.6 Data Communication (Ethernet Interfaces)
- 1.5.7 Configuration and Management
- 1.5.8 Standards Compliance, General
- 1.5.9 Environmental
- 1.5.10 Mechanical and Electrical
- 1.5.11 Antennas
- Chapter 2 - Commissioning of the Macro BTS
- 2.1 Initial NPU Configuration
- 2.2 Completing the Site Configuration Using AlvariSTAR
- Chapter 3 - Operation and Administration of the Macro BTS
- 3.1 Using the Command Line Interface
- 3.1.1 Managing the Macro Outdoor BTS
- 3.1.2 Accessing the CLI
- 3.1.3 Command Modes
- 3.1.4 Interpreting the Command Syntax
- 3.1.5 Using the CLI
- 3.1.6 Managing Users and Privileges
- 3.1.7 Managing Secure Shell (SSH) Parameters
- 3.1.8 Managing the Session
- 3.2 Managing Software Upgrade
- 3.1 Using the Command Line Interface
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface
4Motion 74 System Manual
“Managing Secure Shell (SSH) Parameters” on page 92
“Managing the Session” on page 94
3.1.1 Managing the Macro Outdoor BTS
The following section describe the CLI when using it to manage the Indoor Macro
BTS equipment. The same CLI is used also to manage the Macro Outdoor BTS
equipment, with the following changes:
3.1.1.1 CSCD Port and Local Management
There is no CSCD port in the Macro Outdoor BTS. Local Management may be
supported only on the Management port (in in-band or unified connectivity mode).
It should be noted that local management will be blocked if connectivity mode is
set to out-of-band.
3.1.1.2 Management Port
In the Macro Outdoor BTS the management port is marked MNG, while in the
Indoor BTS it is marked MGMT. All references to MGMT port are applicable to the
MNG port of the Macro Outdoor BTS.
3.1.1.3 AVU, PIU and PSU
AVU and its Fans, PIUs and PSUs do not exist in the Macro Outdoor BTS. These
shelf components cannot be manage and the status of all the following is
indicated as existing and healthy:
2 PIUs
4 PSUs
AVU
10 AVU Fans
3.1.1.4 Alarm In/Out Connectors and Dry-Contacts Management
Alarm In-Out connectors do not exist in the Macro Outdoor BTS. All commands
related to dry-contact in/out are not applicable.
3.1.1.5 Power Feeder
Power Feeders are not applicable for the Macro Outdoor BTS