RSSI Measurement and Maximum Data Rate Configuration
BreezeACCESS MMDS Series 19 SU A/E Subscriber Units Installation Manual
6. RSSI MEASUREMENT AND MAXIMUM DATA
RATE CONFIGURATION
6.1 Performing the RSSI Measurement
The Average RSSI Continuous Display test allows a continuously updated
display of the average Received Signal Strength Indication. As the test measures
only the desired signal of properly received frames, it is a good indication to the
quality of the received signal.
Note: As the RSSI bar indicator is not accurate, it is recommended always to
perform the Average RSSI Continuous Display test after the antenna was
optimally aligned.
1. Start the Monitor program as described in Section 3.1.
2. From the
Main Menu
Type 4 to access the
Site
Survey
menu
.
3. Type 4 to activate the Average RSSI Continuos Display selection screen.
4. On the screen you will get a continuously updated display of RSSI
measurements. To stop the test, press the Esc key.