Basic Installation
BreezeACCESS MMDS Series 7 SU A/E Subscriber Units Installation Manual
2.5 Installing the Outdoor Unit
2.5.1 Pole Mounting the Outdoor Unit
The Outdoor unit can be secured to the pole using one of the following options:
• Special brackets and open-ended screws (supplied with each unit). There
are two pairs of screw holes, allowing use of the special brackets with
various pole widths.
• U-bolts – size A (inner installation holes, up to 2” pole).
• U-bolt – size B (outside installation holes, up to 3” pole).
• Metal bands (9/16” wide, minimum 12” long).
Figure 2-3 shows the locations of the holes, grooves and screw holes on the rear
side of the Outdoor unit.
Figure 2-4 illustrates the method of installing an SU-RA Outdoor unit on a pole,
using the brackets and open-ended screws.
Figure 2-5 illustrates the method of installing an SU-RE Outdoor unit on a pole,
using the brackets and open-ended screws.
Note: Make sure to install the unit with the bottom panel (the panel with the IF
connector) facing downward.
Bracket Screws
Grooves for Insertion of 9/16” Metal Band
U-Bolts (3” Pole)
U-Bolts (2” Pole)
Figure 2-3. Holes/Grooves/Screw holes