User's Manual
Verifying Correct Operation
BS Equipment Installation Manual 20 BreezeACCESS MMDS Series
4. VERIFYING CORRECT OPERATION
4.1 Verifying Correct Operation of the AU-A/E-BS
After completing the installation as described above, the system starts operation.
To verify correct operation, view the LED indicators located on the front panel of
the BS-AU modules as shown in Table 2-2 on page 11.
Note: If the Access Units are not synchronized, reset the Master BS-AU unit and
then the Slave units to re-synchronize them.
4.2 Verifying Correct Operation of the AU-A/E-NI
To verify proper operation, view the LED indicators located on the front and rear
panels of the AU-NI unit as described in Table 4-1.
Table 4-1: AU-NI LEDs
Name Description Functionality
PWR Power Supply
12VDC
On – 12VDC power is supplied to the AU-NI
Off –Power is not supplied to the AU-NI
WLNK Wireless link
activity
Blinking –Receiving packet from the
wireless link
Off – No reception of packets from the
wireless link
ETH connector
embedded LED
Ethernet
activity
On – Receive/transmit on Ethernet port
Off – No receive/transmit on Ethernet port
ETH connector
embedded LED
ETH Link
activity
On – Unit is connected to Ethernet segment
Off – Unit is not connected to Ethernet
segment