User's Manual
Configuring System Parameters
BreezeACCESS MMDS Series 19 BS Equipment Installation Manual
enter the required shift. Type 8 to access the Hopping Sync selection screen.
Enter the required hopping sync status (Master or Slave).
Note: Only one AU should be defined as a Master. The other units should be
defined as slaves. If only one AU is used, it should be defined as Idle.
3.3 Reset Unit
1. From the main menu, type 2 to access the Unit Control menu.
2. Type 1 to access the Reset Unit menu. Type 1 to reset the unit so that new
configuration settings are applied.
Note: Should you make any mistakes during configuration or encounter any
problems associated with system configuration parameters, you may
configure the unit back to the factory defaults, as follows:
Type 2 in the Unit Control menu to access the Set Factory Defaults menu.
Type in 2 (Set Factory defaults-Full) to load the default values. Reset the
unit for the factory defaults values to take effect.