User's Manual

Verifying correct operation
BreezeACCESS MMDS Series 23 BS Equipment Installation Manual
4. VERIFYING CORRECT OPERATION
4.1 Verifying Correct Operation of the AU-A/E-BS
After completing the installation as described above, the system starts operation.
To verify correct operation, view the LED indicators located on the front panel of
the BS-AU modules as shown in Table 2-2on page 12.
Note: If the Access Units are not synchronized, reset the Master BS-AU unit and
then the Slave units to re-synchronize them.
4.2 Verifying Correct Operation of the AU-A/E-NI
To verify proper operation, view the LED indicators located on the front panel of the
AU-NI unit as described in Table 4-1.
Table 4-1: AU-RA/RE Outdoor Unit LEDs
Name Description Functionality
ALARM Alarm
Indication
On – A problem with the power amplifier or in
the locking process of any of the synthesizers
Off –Normal operation
WLNK Wireless link
activity
Blinking –Receiving packet from the wireless
link
Off – No reception of packets from the wireless
link
ETH Ethernet
activity
Blinking – Data received from or transmitted to
Ethernet LAN
Off – No activity on the Ethernet LAN
RSSI Bar display
Displays the Received Signal Strength Indication.
The higher the number of green LEDs that are
ON, the higher the level of the received signal.