User's Manual
Configuring System Parameters
BreezeACCESS MMDS Series 19 BS Equipment Installation Manual
4. Operate the monitor program as follows:
• Type an option number to open/activate the option. You may need
to press the Enter key in some cases.
• Press the Esc key to exit a menu or an option.
• You can log-out and exit the monitor program at any time by
simultaneously pressing the Ctrl and X keys.
• Reset the unit after making configuration changes for the new values
to take effect.
• You can view the current parameters’ configuration by selecting 1 in
the Main Menu to Access the Info Screens menu, and then selecting
2 in the Info Screens menu to view the Basic Configuration
parameters.
3.2 Configuration Parameters
The following system parameters must be configured for each Access Unit:
• ESSID
• IP Address
• Subnet Mask
• Default Gateway Address
• Hopping Band
• Frequency Offset
• Hopping Shift (if using two or more AUs)
• Hopping Sync (if using two or more AUs)
Note: You must select Reset Unit in the Unit Control menu for the changes to take
effect.