BreezeACCESS MMDS Subscriber Units SU-A-D-MMDS Series SU-E-D-MMDS Series Installation Manual July, 2000 Cat. No.
Front Matter © 2000 by BreezeCOM Ltd. All rights reserved. No part of this publication may be reproduced in any material form without the written permission of the copyright owner. Trade Names BreezeACCESS, BreezeNET, BreezeLINK, BreezeVIEW, BreezeMANAGE and WIX are trade names of BreezeCOM Ltd. Other brand and product names are registered trademarks or trademarks of their respective companies. Statement of Conditions The information contained in this manual is subject to change without notice.
Front Matter limited to, loss of profits or revenues, loss of use or damage to any associated equipment, cost of capital, cost of substitute products, facilities or services, downtime costs or claims resulting from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, service, repair, maintenance or use of the products. In no event shall the company’s liability exceed the purchase price denoted on the invoice.
Table of Contents 1. INTRODUCTION ..................................................................................................................... 1 2. BASIC INSTALLATION ......................................................................................................... 2 2.1 Packing List........................................................................................................................... 2 2.2 Other Items Required for Installation.............................................
Table of Contents 7.2 Verifying Data Connectivity ............................................................................................... 22 8. SPECIFICATIONS ................................................................................................................. 23 8.1 Radio ................................................................................................................................... 23 8.2 Data Communication ...........................................................
Table of Contents Table of Figures Figure 2-1. SU-A General Installation Scheme......................................................................... 3 Figure 2-2. SU-E General Installation Scheme ......................................................................... 4 Figure 2-3. Holes/Grooves/Screw holes.................................................................................... 8 Figure 2-4. SU-RA 2" Pole Mounting Installation Using the Supplied Brackets ..................... 8 Figure 2-5.
Introduction 1. INTRODUCTION This manual describes installation guidelines for BreezeACCESS MMDS SU-A and SU-E series of Subscriber Units. The BreezeACCESS IP Broadband Wireless Local Loop (WLL) system allows access service providers to provide high-speed IP connectivity services to their subscribers. To effectively support IP-based services BreezeACCESS systems employ wireless packet data switching technology.
BASIC Installation 2. BASIC INSTALLATION 2.1 Packing List • SU-NI Indoor unit • Outdoor unit ⇒ SU-RA with integral antenna or ⇒ SU-RE with a connector to an external antenna (not included) • SU-PS power supply with a mains power cord • Pole mounting kit for the Outdoor unit (with two brackets, four sets of screws, nuts and washers) • Wall mounting kit for the SU-NI unit 2.
BASIC Installation 2.3 General Installation Scheme Figure 2-1 depicts the general installation scheme for BreezeACCESS SU-A MMDS Subscriber Units; Figure 2-2 depicts the general installation scheme for BreezeACCESS SU-E MMDS Subscriber Units. O U TD O O R U N IT G R O U N D IN G C A B LE IF C A BL E TO O U TD O O R U N IT IN D O O R U N IT TO M A IN S P O W ER S U P P LY TO TE LE P H O N E E Q U IP M E N T (S U -D V S E R IES O N LY ) TO D ATA E Q U IP M E N T Figure 2-1.
BASIC Installation TO A N TE N N A O U TD O O R U N IT G R O U N D IN G C A B LE IF C A BL E TO O U TD O O R U N IT IN D O O R U N IT TO M A IN S TO TE LE P H O N E E Q U IP M E N T (S U -D V S E R IES O N LY ) P O W ER S U P P LY TO D ATA E Q U IP M E N T Figure 2-2.
BASIC Installation 2.4 Guidelines for Selection of Equipment Locations Select appropriate locations for the Outdoor unit and for the Indoor unit using the following guidelines. SU-RA • The SU-RA Outdoor unit should be mounted on a pole and should be installed on a rooftop or a side-wall where a direct line of sight with the Base Station antenna can be established. The higher the unit, the better the achievable link quality.
BASIC Installation Maximum cable Length (m) • 30 100 65 150 The Indoor unit should be installed in as close as possible to the building’s entry point of the IF cable. The location of the Indoor unit should also take into account the need to connect it to a power mains outlet and to the CPE.
BASIC Installation 2.5 Installing the Outdoor Unit 2.5.1 Pole Mounting the Outdoor Unit The Outdoor unit can be secured to the pole using one of the following options: • Special brackets (supplied with each unit). There are two pairs of screw holes, allowing use of the special brackets with various pole widths. • U-bolts – size A (inner installation holes, up to 2” pole). • U-bolt – size B (outside installation holes, up to 3” pole). • Metal bands (9/16” wide, minimum 12” long).
BASIC Installation G roo ve s fo r Insertion of 9 /16 ” M etal B a nd U -B olts (3” P o le) U -B olts (2” P o le) B ra cket S crew s Figure 2-3. Holes/Grooves/Screw holes Figure 2-4.
BASIC Installation Figure 2-5.
BASIC Installation 2.5.2 Connecting the Antenna Cable (SU-RE) Connect an RF cable between the ANT connector (located on the top panel of the SU-RE unit) and the antenna. 2.5.3 Connecting the Ground and IF Cables The Ground terminal (marked ) and the IF cable connector (marked IF) are located on the bottom panel of the SU-RA Outdoor unit, shown in Figure 4-1. 1. Connect one end of the ground cable to the Ground terminal and connect the other end to a good ground connection. 2.
BASIC Installation ETH DC - 12V IF Figure 2-6. SU-NI Rear Panel 5. Verify that the Power LED (marked PWR) located on the front panel of the Indoor Unit is turned ON. PW R MON W LNK Figure 2-7. SU-NI Front Panel 6. Use a straight Ethernet 10baseT cable to connect a PC (SU-A/E -1D), or a hub (SU-A/E-8D or SU-A/E-BD) to the Ethernet port (marked ETH) located on the rear panel of the SU-NI unit.
Configuring System Parameters 3. CONFIGURING SYSTEM PARAMETERS After completing the installation process, as described in the preceding section, proceed with the configuration of the basic system parameters. This section covers the configuration of basic installation parameters. Refer to the Administration Manual for information related to other parameters. Note: Optionally, the product can be configured using Telnet over the Ethernet port, after setting IP address.
Configuring System Parameters Unit Type BreezeACCESS (SU-1D) Official Release Version – 2.1.1 Release Date: Software Version No. Tue Mar 07 11:21:22 2000 Main Menu ===================== 1 – Info Screens 2 – Unit Control 3 – Basic Configuration 4 – Site Survey 5 – Advanced Configuration BreezeACCESS >>> Unit Name Figure 3-1. Main Menu The appearance of the displayed Main Menu varies in accordance with the access level.
Configuring System Parameters • Type an option number to open/activate the option. You may need to press the Enter key in some cases. • Press the Esc key to exit a menu or an option. • You can log-out and exit the monitor program at any time by simultaneously pressing the Ctrl and X keys. • Reset the unit after making configuration changes for the new values to take effect.
Configuring System Parameters 1. From the main menu, type 3 to access the Basic Configuration menu. BreezeACCESS (SU-1D) Official Release Version – 2.1.1 Release Date: Tue Mar 07 11:21:22 2000 Basic Configuration ==================== 1 – IP Address 2 – Subnet Mask 3 – Default Gateway Address 4 – ESSID 5 – Maximum Data Rate 6 – Frequency Offset 7 – Hopping Band X - Transmit Power Control Y - Receive Attenuation Control S - Show Basic Configuration BreezeACCESS >>> Figure 3-2. Basic Configuration Menu 2.
Configuring System Parameters 3.3 Reset Unit 1. From the main menu, type 2 to access the Unit Control menu. 2. Type 1 to access the Reset Unit menu. Type 1 to reset the unit so that new configuration settings are applied. Note: Should you make any mistakes during configuration or encounter any problems associated with system configuration parameters, you may configure the unit back to the factory defaults, as follows: Type 2 in the Unit Control menu to access the Set Factory Defaults menu.
Aligning the Antenna 4. ALIGNING THE ANTENNA Note: Antenna alignment using the RSSI bar display is possible only after the Access Unit you wish to associate with is operational and the ESSID, Hopping Band and Frequency Offset parameters were properly configured. Otherwise the unit will not be able to synchronize and associate with the Access Unit. As the RSSI measurement is performed on received frames, its results are meaningless as long as the unit is not associated with an AU. 1.
Aligning the Antenna 4. For proper operation, at least one green LED should be ON. If you cannot reach a point where at least one green LED is ON, try to improve the reception quality by placing the antenna at a higher point or in a d9ifferent location. Note: In some cases (e.g., when the Subscriber Unit is very close to the Base Station), the antenna might have to be installed at an appropriate angle, in order to ensure that it is directed towards the Base Station antenna). 5.
Verifying Correct Operation of the Outdoor Unit 5. VERIFYING CORRECT OPERATION OF THE OUTDOOR UNIT To verify correct operation, view the LED indicators located on the bottom panel of the Outdoor unit as shown in Figure 4-1 on page 17. The following table lists the various LED states.
RSSI Measurement and Maximum Data Rate Configuration 6. RSSI MEASUREMENT AND MAXIMUM DATA RATE CONFIGURATION 6.1 Performing the RSSI Measurement The Average RSSI Continuous Display test allows a continuously updated display of the average Received Signal Strength Indication. As the test measures only the desired signal of properly received frames, it is a good indication to the quality of the received signal.
RSSI Measurement and Maximum Data Rate Configuration 6.2 Configuring The Maximum Data Rate 5. Use the following table to determine the recommended Maximum Data Rate. Table 3: RSSI vs. Maximum Data Rate RSSI Maximum Data Rate Higher than 97 3 Mbps From 86 to 97 2Mbps Lower than 86* 1 Mbps * If the RSSI is lower than 80 units the link quality is too low and should be improved through installing the antenna in a different and/or a higher location. 2.
Verifying Correct Operation 7. VERIFYING CORRECT OPERATION 7.1 General After completing the installation as described above, the system starts operation. To verify correct operation, view the LED indicators located on the front panel of the SU-NI Indoor unit as shown in Figure 2-7 on page 11. Table 4 lists the various LED states.
Specifications 8. SPECIFICATIONS 8.1 Radio Frequency 2.500GHz – 2.686GHz Radio Access Method FH-CDMA or TDMA Operation Mode Time Duplex Division Sub-Channel Bandwidth 1 MHz Frequency Setting Resolution 1 MHz Antenna Gain (SU-RA) 17dBi, 20o Output Power (at antenna port) 27 dBm typical.
Specifications 8.2 Data Communication Standard Compliance IEEE 802.3 CSMA/CD 8.3 Outdoor Unit to Indoor Unit Communication IF Frequency 440 MHz IF cable Impedance 50 ohm Maximum IF cable Attenuation 15dB Maximum IF cable DC Resistance 1.5 ohm 8.
Specifications 8.5 Interfaces Interface Outdoor unit IF TNC jack, lightning protected RF (SU-E) N-Type jack SU-NI indoor unit TNC jack, lightning protected Ethernet 10Base-T (RJ-45) with 2 embedded LEDs Monitor 3-pin low profile Power 12 VDC via the IF cable DC Plug for the SU-PS power supply 8.
Appendix A SU A/E Subscriber Units Installation Manual 26 BreezeACCESS MMDS Series
Appendix A. Using Telnet APPENDIX A. USING TELNET Use the following procedure to connect to BreezeACCESS MMDS units via a Telnet session. 1. Connect the PC to the Ethernet port of the unit (or the hub to which the unit is connected) using a straight Ethernet cable. If you connect the PC directly to a unit that is normally connected to a hub, use a crossed Ethernet cable.