Appendix A - Wiring 10Base-T Jacks
Table 3-1: Monitor Port Communication Parameters
Parameter Value
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Flow Control Xon/Xoff
Connector Connected COM port
NOTE
Following three unsuccessful login attempts (using incorrect passwords) from
either the Monitor port or via Telnet, the monitor program is blocked for several
minutes. To enable access to the monitor program during that time, the unit must
be reset via SNMP or by disconnecting/reconnecting power.
To access the Monitor Program locally using Telnet:
1. Connect a PC to the Ethernet port using a crossover cable.
2. Configure the PC’s IP parameters to enable connectivity with the
unit. The default IP address is 10.0.0.1.
3. Run the Telnet program. The Select Access Level menu is displayed.
4. Select the required access level, depending on your specific access
rights. A password entry request is displayed.
5. Enter your password and press Enter. The Main Menu is displayed.
NOTE
If the Telnet session is not terminated properly, for example, if you simply close
the window, the monitor program is blocked for several minutes. To enable
access to the monitor program during that time, the unit must be reset via SNMP
or by disconnecting/reconnecting power.