Set-up and Initialization
Set-up and Initialization
After completing the installation process, as described in the preceding
chapter, the basic parameters must be configured to ensure that the
unit operates correctly. Once the basic parameters have been
configured, additional parameters can be remotely configured via the
Ethernet port or the wireless link using Telnet or SNMP management, or
by loading a configuration file.
NOTE
The decision on hopping frequencies to be used, based on the results of the
Spectrum Analysis survey, must be made prior to starting the process of
configuring basic parameters.
Accessing the Monitor Program
To access the Monitor Program using the Monitor cable:
To configure the Cell Extender, use the Dual Monitor cable to connect
the Ethernet connector of the unit to the COM port of a PC running a
terminal emulation program. The COM port connectors on the Dual
Monitor cable are 9-pin D-type plugs. One plug connects to the SU
interface module inside the unit and the other plug connects to the AU
module.
To configure the SU-I, use a regular Monitor cable.
1. Run a terminal emulation program, such as HyperTerminal™.
2. Set the communication parameters as shown in . Table 3-1
3. Press Enter. The Select Access Level menu is displayed.
4. Select the required access level, depending on your specific access
rights. A password entry request is displayed.
5. Enter your password and press Enter. The Main Menu is displayed.
Manual Revision 1.0 - Preliminary
A
-3